My Cart [ 0 ]
New Products
New Services
Promotions
News
Home > Anti-Human Antibodies for Flow Cytometry
Primary antibodies against human target proteins, such as PD 1 and PD L1 proteins. The anti-human antibodies are for flow cytometry.
    37 Anti-Human Antibodies for Flow Cytometry Products
  • PA007511.m1: Non-conjugated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: 4G7), Mouse IgG1 Kappa

    Recombinant mouse IgG1 Monoclonal Antibody.
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant 4G7 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F).

     

    PA007511.h1Fs: Non-conjugated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: 4G7), Human IgG1 Fc Silent Kappa

    Recombinant human IgG1 monoclonal antibody with Fc silent mutation.
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant 4G7 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F).

     

    PA007745.m1-b: Biotinylated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: 4G7), Mouse IgG1 Kappa

    Recombinant Mouse IgG1 Monoclonal Antibody with site-directed  biotinylation through the Avi tag at the C-terminus of the antibody heavy chain.
    Conjugation: Biotin-conjugated.
    Specificity/Sensitivity: The site-directed biotinylated recombinant 4G7 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC) with various dye conjugation through streptavidin; conjugation to streptavidin agarose beads or streptavidin magnetic beads.

     

  • PA007423.m2a: Non-conjugated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: B43), Mouse IgG2a Kappa

    Recombinant  mouse IgG2a Monoclonal Antibody. 
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant B43 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007423.h1Fs: Non-conjugated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: B43), Human IgG1 Fc Silent Kappa

    Recombinant human IgG1 monoclonal antibody with Fc silent mutation.
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant B43 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007744.m2a-b: Biotinylated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: B43), Mouse IgG2a Kappa

    Recombinant mouse IgG2a monoclonal antibody with site-directed  biotinylation through the Avi tag at the C-terminus of the antibody heavy chain.
    Conjugation: Biotin-conjugated.
    Specificity/Sensitivity: The site-directed biotinylated recombinant B43 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC) with various dye conjugation through streptavidin; conjugation to streptavidin agarose beads or streptavidin magnetic beads.

  • PA007422.m2a: Non-conjugated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: FMC63), Mouse IgG2a Kappa

    Recombinant  mouse IgG2a Monoclonal Antibody. 
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant FMC63 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007422.h1Fs: Non-conjugated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: FMC63), Human IgG1 Fc Silent Kappa

    Recombinant human IgG1 monoclonal antibody with Fc silent mutation.
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant FMC63 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007743.m2a-b: Biotinylated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: FMC63), Mouse IgG2a Kappa

    Recombinant mouse IgG2a monoclonal antibody with site-directed biotinylation through the Avi tag at the C-terminus of the antibody heavy chain.
    Conjugation: Biotin-conjugated.
    Specificity/Sensitivity: The site-directed biotinylated recombinant FMC63 antibody specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC) with various dye conjugation through streptavidin; conjugation to streptavidin agarose beads or streptavidin magnetic beads.

     

  • PA007283.m1: Non-conjugated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: SJ25C1)

    Recombinant  mouse IgG1 Monoclonal Antibody. 
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant mouse monoclonal antibody (clone: SJ25C1) specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007283.h1Fs: Non-conjugated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: SJ25C1), Human IgG1 Fc Silent Kappa

    Recombinant  human IgG1 Monoclonal Antibody. 
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant mouse monoclonal antibody (clone: SJ25C1) specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007284.m1-b: Biotinylated Recombinant Anti-human CD19 Monoclonal Antibody (Clone: SJ25C1)

    Recombinant mouse IgG1 monoclonal antibody with site-directed  biotinylation through the Avi tag at the C-terminus of the antibody heavy chain.
    Conjugation: Biotin-conjugated.
    Specificity/Sensitivity: The site-directed biotinylated recombinant mouse monoclonal antibody (clone: SJ25C1) specifically binds to the human CD19 protein.
    Applications: Flow cytometry (FC) with various dye conjugation through streptavidin; conjugation to streptavidin agarose beads or streptavidin magnetic beads.

     

  • PA007331.m1: Non-conjugated Recombinant Anti-human CD16 Monoclonal Antibody (Clone: 3G8), Mouse IgG1 kappa

    Recombinant  mouse IgG1 Monoclonal Antibody. 
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant mouse monoclonal antibody (clone: 3G8) specifically binds to human and non-human primate CD16.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007331.h1Fs: Non-conjugated Recombinant Anti-human CD16 Monoclonal Antibody (Clone: 3G8), Human IgG1 Fc Silent Kappa

    Recombinant  human IgG1 Monoclonal Antibody. 
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant mouse monoclonal antibody (clone: 3G8) specifically binds to human and non-human primate CD16.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007332.m1-b: Biotinylated Recombinant Anti-human CD16 Monoclonal Antibody (Clone: 3G8), Human IgG1 Fc Silent Kappa

    Recombinant  mouse IgG1 monoclonal antibody with site-directed biotinylation through the Avi tag at the C-terminus of the antibody heavy chain. 
    Conjugation: Biotin-conjugated.
    Specificity/Sensitivity: The site-directed biotinylated recombinant 3G8 antibody specifically binds to human and non-human primate CD16.
    Applications: Flow cytometry (FC) with various dye conjugation through streptavidin; conjugation to streptavidin agarose beads or streptavidin magnetic beads.

     

  • PA007299.m2a: Non-conjugated Recombinant Anti-human Siglec-2/CD22 Monoclonal Antibody (Clone: NCI m971), Mouse IgG2a kappa

    Recombinant  mouse IgG2a monoclonal antibody. 
    Conjugation: Non-conjugated.
    Specificity/Sensitivity: The recombinant mouse monoclonal antibody (clone: NCI m971) specifically binds to the human Siglec-2/CD22 protein.
    Applications: Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). 

     

    PA007300.m2a-b: Biotinylated Recombinant Anti-human Siglec-2/CD22 Monoclonal Antibody (Clone: NCI m971), Mouse IgG2a kappa

    Recombinant mouse IgG2a monoclonal antibody with site-directed biotinylation through the Avi tag at the C-terminus of the antibody heavy chain.
    Conjugation: Biotin-conjugated.
    Specificity/Sensitivity: The site-directed biotinylated recombinant mouse monoclonal antibody (clone: NCI m971) specifically binds to the human Siglec-2/CD22 protein.
    Applications: Flow cytometry (FC) with various dye conjugation through streptavidin; conjugation to streptavidin agarose beads or streptavidin magnetic beads.

     

  • PA007396: Recombinant Mouse IgG1 Isotype Control Antibody

    Isotype: mouse IgG1 kappa.
    Specificity/Sensitivity: HEL-specific; neither human nor mouse samples.
    Applications: ELISA, flow cytometry, immunoblotting, immunoprecipitation, immunocytochemistry, immunofluorescence, and isotype controls.

     

    PA007397: Recombinant Mouse IgG2a Isotype Control Antibody

    Isotype: mouse IgG2a kappa.
    Specificity/Sensitivity: HEL-specific; neither human nor mouse samples.
    Applications: ELISA, flow cytometry, immunoblotting, immunoprecipitation, immunocytochemistry, immunofluorescence, and isotype controls.

     

    PA007398: Recombinant Mouse IgG2b Isotype Control Antibody

    Isotype: mouse IgG2b kappa.
    Specificity/Sensitivity: HEL-specific; neither human nor mouse samples.
    Applications: ELISA, flow cytometry, immunoblotting, immunoprecipitation, immunocytochemistry, immunofluorescence, and isotype controls.

     

    PA007399: Recombinant Mouse IgG2c Isotype Control Antibody

    Isotype: mouse IgG2c kappa.
    Specificity/Sensitivity: HEL-specific; neither human nor mouse samples.
    Applications: ELISA, flow cytometry, immunoblotting, immunoprecipitation, immunocytochemistry, immunofluorescence, and isotype controls.

     

    PA007400: Recombinant Mouse IgG3 Isotype Control Antibody

    Isotype: mouse IgG3 kappa.
    Specificity/Sensitivity: HEL-specific; neither human nor mouse samples.
    Applications: ELISA, flow cytometry, immunoblotting, immunoprecipitation, immunocytochemistry, immunofluorescence, and isotype controls.

     

See our Privacy Policy