MB038-4G: 4G One-step RT-PCR Kit
MB038-4Gb: 4G One-step RT-PCR Kit with blue dye
The kit is provided in a convenient Master Mix format. The 2 x One-step Mix contains optimized buffer system, dNTP and loading dye; One-step Enzyme Mix contains optimized ratio of 4G Reverse Transcriptase, Murine RNase inhibitor, and hot start Taq DNA polymerase.
* High efficiency. Integrating the superior performance of 4G Reverse Transcriptase and hot-start Taq DNA Polymerase, with an optimized buffer system, the detection sensitivity of the 4G One Step RT-PCR Kit can reach 1 pg total RNA and can be amplified Fragments up to 10 kb.
* High purity. >98% homogeneous of the Taq DNA polymerase by SDS gel electrophoresis. No contamination detected in standard PCR test reactions.
* Reproducible results.
* Reverse transcription and PCR reactions are completed in one tube, no additional tube opening/pipetting operations are required, which improves detection throughput and reduces the risk of contamination.MB129-5G: Probe-Based 5G One-Step qRT-PCR Kit
* Using gene specific primers (GSP), the reverse transcription and qPCR can be finished in one tube, significantly reducing pipetting procedures and the risk of contamination.
* More sensitive amplification that is suitable for DNA and RNA templates.
* More stable amplification curve with low concentration template.
* Better storage conditions.
* It supports rapid procedures and is suitable for rapid reactions.MB129-4G: Probe-Based 4G One-Step qRT-PCR Kit
* Using gene specific primers (GSP), the reverse transcription and qPCR can be finished in one tube, significantly reducing pipetting procedures and the risk of contamination.
* More sensitive amplification that is suitable for DNA and RNA templates.
* More stable amplification curve with low concentration template.
* Better storage conditions.
* It supports rapid procedures and is suitable for rapid reactions.MB130: Probe-Based Multiplex One-Step qRT-PCR Kit
* Using gene specific primers (GSP), the reverse transcription and qPCR can be finished in one tube, significantly reducing pipetting procedures and the risk of contamination.
* More sensitive amplification that is suitable for DNA and RNA templates.
* More stable amplification curve with low concentration template.
* Better storage conditions.
* It supports rapid procedures and is suitable for rapid reactions.MB128: Dye-Based One-Step qRT-PCR Kit
* Using gene specific primers (GSP), the reverse transcription and qPCR can be finished in one tube, significantly reducing pipetting procedures and the risk of contamination.
* High detection sensitivity of one step qRT-PCR SYBR green kit: 1 pg total RNA.
* More stable amplification curve with low concentration template.
* Reduced formation of primer dimers and improved specificity of qPCR products.
* Convenient, easy, and quick operation.