My Cart [ 0 ]
Home > Antibodies > Primary Antibodies for Epitope Tags  > Recombinant Anti-Fluorescein Antibody (Clone: 4-4-20 Enhanced)

Recombinant Anti-Fluorescein Antibody (Clone: 4-4-20 Enhanced)

Anti-FITC Monoclonal Antibody

Catalog No. Product Name Size List Price (US$) Quantity
PA007702.m2a Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG2a Kappa 200 ug 100.00
PA007702.m2a Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG2a Kappa 1 mg 150.00
PA007702.m1 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG1 Kappa 200 ug 250.00
PA007702.m1 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG1 Kappa 1 mg 500.00
PA007702.m2b Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG2b Kappa 200 ug 250.00
PA007702.m2b Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG2b Kappa 1 mg 500.00
PA007702.m2c Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG2c Kappa 200 ug 250.00
PA007702.m2c Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG2c Kappa 1 mg 500.00
PA007702.m3 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG3 Kappa 200 ug 250.00
PA007702.m3 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse IgG3 Kappa 1 mg 500.00
PA007702.mf Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse F(ab) Kappa 1 mg 900.00
PA007702.h1 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG1 Kappa 200 ug 250.00
PA007702.h1 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG1 Kappa 1 mg 500.00
PA007702.h2 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG2 Kappa 200 ug 250.00
PA007702.h2 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG2 Kappa 1 mg 500.00
PA007702.h3 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG3 Kappa 200 ug 250.00
PA007702.h3 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG3 Kappa 1 mg 500.00
PA007702.h4 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG4 Kappa 200 ug 250.00
PA007702.h4 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG4 Kappa 1 mg 500.00
PA007702.hf Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human F(ab) Kappa 1 mg 900.00
PA007702.r1 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rat IgG1 Kappa 200 ug 250.00
PA007702.r1 Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rat IgG1 Kappa 1 mg 500.00
PA007702.r2a Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rat IgG2a Kappa 200 ug 250.00
PA007702.r2a Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rat IgG2a Kappa 1 mg 500.00
PA007702.r2b Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rat IgG2b Kappa 200 ug 250.00
PA007702.r2b Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rat IgG2b Kappa 1 mg 500.00
PA007702.r2c Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rat IgG2c Kappa 200 ug 250.00
PA007702.r2c Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rat IgG2c Kappa 1 mg 500.00
PA007702.rt Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rabbit IgG Kappa 200 ug 250.00
PA007702.rt Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Rabbit IgG Kappa 1 mg 500.00
PA007702.h1LA Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG1-L234A L235A P329G (LALAPG) Kappa 200 ug 250.00
PA007702.h1LA Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human IgG1-L234A L235A P329G (LALAPG) Kappa 1 mg 500.00
PA007702.hfhis Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Human Fab fragment Kappa (His-tag) 1 mg 900.00
PA007702.mfhis Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Mouse Fab fragment Kappa (His-tag) 1 mg 900.00
PA007702.g Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Goat IgG Kappa 200 ug 250.00
PA007702.g Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced)), Goat IgG Kappa 1 mg 500.00
PA007702.scFv Recombinant Anti-Fluorescein scFv (Clone: 4-4-20 (enhanced)), His Tag 1 mg 900.00
Description

Background of Recombinant Anti-Fluorescein Monoclonal Antibody (Clone: 4-4-20 (enhanced))

Our Recombinant Anti-Fluorescein Antibody (Clone 4-4-20 enhanced) is a sequence-defined, mammalian-expressed anti-FITC monoclonal antibody that specifically recognizes the fluorescein core structure attached to proteins, peptides, nucleic acids, or solid matrices. As a highly stable and reliable anti-fluorescein hapten antibody, this recombinant molecule serves as an essential second-step detection reagent for identifying fluorescein-labeled targets and amplifying signals across various standard in vitro immunoassays, completely avoiding the risk of hybridoma genetic drift. The fluorescein/anti-fluorescein detection system offers a critical advantage over traditional biotin-streptavidin methods. Because biotin is naturally present in a large variety of mammalian tissues and cell lysates, biotin-based assays frequently suffer from high background noise and false-positive results. In contrast, fluorescein is completely absent in biological samples. Utilizing our recombinant anti-FITC monoclonal antibody entirely eliminates endogenous background interference. This makes our anti-fluorescein hapten antibody the ideal choice for achieving ultra-clean, accurate data in complex in vitro diagnostics, ELISA, and high-throughput screening platforms. We offer comprehensive custom engineering and scale-up manufacturing specifically for the Clone 4-4-20 enhanced framework to support diagnostic kit developers and academic labs. Available configurations include:

  • Isotype Switching & Fc Engineering: Various heavy/light chain isotypes and engineered Fc variants (such as effector-silent LALAPG mutants).
  • Affinity Tags: Recombinant addition of Avi-tag, His-tag, or DYKDDDDK-tag for specific assay orientations.
  • Conjugations: Biotinylated formats, as well as direct conjugations with a wide variety of fluorophores, dyes, and enzymes (HRP/AP).

PA007702.m1: Recombinant Anti-fluorescein Monoclonal Antibody (Clone: 4-4-20 (Enhanced)), Mouse IgG1 Kappa

Recombinant mouse IgG1 Monoclonal Antibody.
Clone: 4-4-20 (enhanced).
Isotype: Mouse IgG1 kappa.
Source: The recombinant anti-Fluorescein monoclonal antibody (clone: 4-4-20 (enhanced)) was produced in mammalian cells.
Specificity/Sensitivity: The recombinant anti-Fluorescein monoclonal antibody (clone: 4-4-20 (enhanced)) specifically binds to Fluorescein.
Applications: Western Blot, Flow Cytometry.
Form of Antibody: 0.2 μM filtered solution of 1x PBS.
Purity: >95% by SDS-PAGE under reducing conditions and HPLC.

Shipping: The recombinant anti-fluorescein monoclonal antibody of clone 4-4-20 (enhanced) is shipped with ice pack. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage: Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
12 months from date of receipt, -20 to -70°C as supplied.
1 month from date of receipt, 2 to 8°C as supplied.

References of Anti-Fluorescein Antibody (Clone: 4-4-20)

Irina V. Safenkova, et al. Food Res Int. 2026 Apr;230:118592. doi: 10.1016/j.foodres.2026.118592. PMID: 41794473
"An isothermal amplification assay integrated with lateral flow test (LFT) was developed for equipment-free detection of Listeria monocytogenes. In both LAMP-LFT and LAMP-CRISPR/Cas12a-LFT formats, fluorescein- and biotin-labeled amplicons were detected using a common conjugate of gold nanoparticles and anti-fluorescein (anti-FAM) antibodies, with a cleaved fork-shaped multi-fluorescein probe enabling visual readout on strips coated with anti-FAM capture antibody. The optimized assay achieved a single-cell detection limit (0.2 cells/reaction in buffer, 1 cell/reaction in spiked milk) within 80 min."
(Tags: gold nanoparticle conjugated anti-fluorescein antibody lateral flow test; anti-FAM antibody LAMP-CRISPR visual amplicon detection)
Manon Bastat, et al. Anal Chem. 2025 Oct;97(41):22497-22507. doi: 10.1021/acs.analchem.5c02284. PMID: 41057037
"A dual chromogenic and fluorescent in situ cytochemistry tool was developed to highlight invisible touch-DNA traces (e.g., fingermark corneocytes) on crime-scene surfaces. Chromogenic labeling of mannose residues and keratin 10 allowed visualization of as few as 100 shed cells, while a combination of FITC-conjugated primary probes and an HRP-conjugated anti-FITC antibody enabled simultaneous chromogenic and fluorescent detection across light and opaque substrates (ceramic, metal), supporting on-field sampling decisions prior to DNA extraction."
(Tags: HRP-conjugated anti-FITC antibody chromogenic in situ labeling; anti-fluorescein antibody forensic cytochemical detection)
Saralee Srivorakul, et al. Vet Sci. 2025 Sep;12(9):845. doi: 10.3390/vetsci12090845. PMID: 41012770
"A reverse-transcriptase recombinase polymerase amplification assay combined with a lateral flow dipstick (RT-RPA-LFD) was developed for point-of-care detection of Tilapia Lake Virus. The dipstick was prepared with immobilized anti-FITC and anti-biotin capture antibodies compatible with TiLV-specific primers tagged with FITC and biotin. Reverse transcription and RPA amplification were completed at 39 °C within 20 min, and products were visualized as a positive band on the LFD, achieving a 3.19 copies/µL limit of detection—a 100-fold improvement over RT-PCR-LFD."
(Tags: anti-FITC capture antibody lateral flow dipstick RPA; anti-fluorescein antibody rapid viral nucleic acid point-of-care detection)
Yong-Hong Luah, et al. Nat Biomed Eng. 2024 Mar;8(3):248-262. doi: 10.1038/s41551-023-01089-z. PMID: 37652987
"PAINTKiller, a flow-cytometry-compatible assay for identifying and sorting functional cytotoxic effector cells in co-cultures, relies on capturing the intracellular carboxyfluorescein succinimidyl ester released from lysed target cells onto the surface of the killing lymphocyte. Capture was achieved using a bispecific complex consisting of an anti-fluorescein isothiocyanate antibody linked to an antibody against the pan-leucocyte receptor CD45, which 'painted' the natural killer cell surface with fluorescent lysate and enabled FACS sorting followed by single-cell RNA-seq profiling of killer-cell subpopulations."
(Tags: anti-fluorescein antibody flow cytometry effector cell sorting; anti-FITC antibody bispecific complex cell-mediated cytotoxicity assay)
Ji Yoon Ryu, et al. Org Biomol Chem. 2024 Oct;22(40):8182-8188. doi: 10.1039/d4ob01311e. PMID: 39291769
"A fluorescein-switching lateral flow assay was developed for naked-eye detection of microRNA biomarkers (miR-6090 and miR-141 for prostate cancer). Reduced fluorescein on the probe only weakly binds gold-nanoparticle-conjugated anti-fluorescein antibodies; in the presence of target microRNA, riboflavin tetraacetate photo-oxidizes the probe back to native fluorescein, which strongly binds the antibodies on the strip to produce a visible line. Sodium borohydride was introduced to minimize background, enabling fmol-level microRNA detection with minimal false positives for point-of-care cancer diagnostics."
(Tags: gold nanoparticle conjugated anti-fluorescein antibody microRNA lateral flow; anti-FAM antibody fluorescein-switching visual nucleic acid detection)
For more technical references or data sheets regarding the Recombinant Anti-Fluorescein Monoclonal Antibody formats, please contact our scientific support team at message@sydlabs.com.

Frequently Asked Questions (FAQ) about Anti-Fluorescein Antibody (Clone: 4-4-20 Enhanced)

Q: Is this anti-fluorescein antibody suitable for both free FITC and FITC-conjugated proteins?

Yes. This high-affinity anti-fluorescein hapten antibody (Clone 4-4-20 enhanced) is specifically raised against the fluorescein ring system. It demonstrates excellent cross-reactivity and tightly binds to both free fluorescein molecules and various FITC-conjugated proteins, antibodies, or dextran targets in solution.

Q: Why should I choose the recombinant 4-4-20 enhanced antibody over traditional hybridoma clones?

Our recombinant anti-FITC monoclonal antibody is sequence-verified and expressed in mammalian cells. Unlike traditional hybridomas that suffer from cell line drift or contaminating antibody light chains, this enhanced version guarantees 100% batch-to-batch reproducibility, ultra-pure target binding, and consistent signal backgrounds for routine in vitro screening.

Q: What are the primary validated applications for the anti-fluorescein monoclonal antibody?

This enhanced 4-4-20 recombinant antibody is fully validated for standard laboratory applications including Western Blotting (WB), Flow Cytometry (FC), Immunoprecipitation (IP), and competitive or sandwich ELISA assays. Its structured binding pocket ensures reliable primary or secondary detection of fluorescein-labeled targets.

Q: Why choose the recombinant version of Clone 4-4-20 over traditional hybridoma-derived antibodies?

Traditional hybridoma cell lines are prone to genetic drift, antibody expression loss, or contamination with unwanted light chains. Our recombinant Clone 4-4-20 is sequence-defined and expressed in mammalian cells, which guarantees 100% batch-to-batch consistency, ultra-high purity (>95% via SDS-PAGE), and a completely animal-free, reproducible manufacturing process.

Q: Are bulk quantities and custom configurations available for this anti-fluorescein antibody?

Yes. Syd Labs specializes in high-throughput scale-up production. We offer bulk quantities of the recombinant anti-fluorescein 4-4-20 antibody for assay kit manufacturing or high-screening diagnostic platforms. Custom services including specific isotype switching, Fc silencing (LALAPG variants), and biotin or enzyme conjugations are available upon request.

Syd Labs provides the following recombinant anti-Biotin/Digoxin/DNP/Fluorescein monoclonal antibodies:
Recombinant Anti-Biotin Monoclonal Antibodies (Clone F1)
Recombinant Anti-Biotin Monoclonal Antibodies (Clone M33)
Recombinant Anti-Digoxin Monoclonal Antibodies (Clone 5A7)
Recombinant Anti-Digoxin Monoclonal Antibodies (Clone 26-10)
Recombinant Anti-DNP Monoclonal Antibodies (Clone DNP.m3)
Recombinant Anti-Fluorescein Monoclonal Antibodies (Clone 4-4-20)
Recombinant Anti-Fluorescein Monoclonal Antibodies (Clone 4M5.3)

Related Links

See our Privacy Policy