My Cart [ 0 ]
Home > Antibodies > Primary Antibodies for Epitope Tags  > Anti-Biotin Monoclonal Antibodies

Anti-Biotin Monoclonal Antibodies

Biotin; Vitamin H; Vitamin B7

Catalog No. Product Name Size List Price (US$) Quantity
PA007706.m2a Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Mouse IgG2a Kappa 200 ug 100.00
PA007706.m2a Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Mouse IgG2a Kappa 1 mg 150.00
PA007706.m1 Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Mouse IgG1 Kappa 200 ug 150.00
PA007706.m1 Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Mouse IgG1 Kappa 1 mg 300.00
PA007706.h1 Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human IgG1 Kappa 200 ug 150.00
PA007706.h1 Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human IgG1 Kappa 1 mg 300.00
PA007706.h1LA Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human IgG1-L234A L235A P329G (LALAPG) Kappa 200 ug 150.00
PA007706.h1LA Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human IgG1-L234A L235A P329G (LALAPG) Kappa 1 mg 300.00
PA007706.h1Fs Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human IgG1 Fc Silent Kappa 200 ug 150.00
PA007706.h1Fs Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human IgG1 Fc Silent Kappa 1 mg 300.00
PA007706.mf Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Mouse Fab Fragment 1 mg 900.00
PA007706.hf Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Human Fab Fragment 1 mg 900.00
PA007706.scFv Recombinant Anti-Biotin scFv (Clone: M33), His Tag 1 mg 900.00
PA007706.rt Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Rabbit IgG 1 mg 300.00
Description

Background of Recombinant Anti-Biotin Monoclonal Antibody

Recombinant mouse anti-biotin antibodies recognize biotin (vitamin B7) attached to proteins, peptides, nucleic acids, or solid matrices, and can be offered in fluorophore and enzyme-conjugated versions.

The anti-biotin monoclonal antibody can be used as a second-step reagent in various applications for detecting biotinylated targets. The biotin-streptavidin system is widely used in immunoassay signal amplification techniques because streptavidin binds biotin with extremely high affinity.

Because biotin is naturally present in a large variety of biological samples, it may affect the results of biotin-based assays, such as reduced sensitivity, false negatives or false positives. Streptavidin/biotin blocking kit, avidin/biotin blocking system, or biotin blockers are used to block signals from endogenous avidin, biotin and biotin-binding proteins in tissues when used with biotin-based IHC detection.

Please contact us to ask for a quote for the engineered anti-biotin antibody mutants of various isotypes, and mutants with Avi-, His-, and DYKDDDDK-tags, and biotinylated antibodies and mutants. A variety of conjugates (such as dyes and fluorophores) with the anti-biotin antibodies and mutants are available.

PA007706.m2a: Recombinant Anti-Biotin Monoclonal Antibody (Clone: M33), Mouse IgG2a Kappa

Recombinant mouse IgG2a Monoclonal Antibody.
Clone: M33.
Isotype: Mouse IgG2a kappa.
Source: The recombinant anti-Biotin monoclonal antibody (clone: M33) was produced in mammalian cells.
Specificity/Sensitivity: The recombinant anti-Biotin monoclonal antibody (clone: M33) specifically binds to Biotin.
Applications: ELISA, Western Blot (WB), Flow Cytometry (Flow), Immunoprecipitation (IP), Immunohistochemistry (Paraffin) (IHC (P)), Immunohistochemistry (Frozen) (IHC (F)).
Form of Antibody: 0.2 μM filtered solution of 1x PBS.
Purity: >95% by SDS-PAGE under reducing conditions and HPLC.

Shipping: The recombinant anti-Biotin monoclonal antibody of clone M33 is shipped with ice pack. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage: Use a manual defrost freezer and avoid repeated freeze-thaw cycles.
12 months from date of receipt, -20 to -70°C as supplied.
1 month from date of receipt, 2 to 8°C as supplied.

References of Anti-Biotin Monoclonal Antibody (Clone: M33)

Mana Hamada, et al. Biochem Biophys Res Commun. 2026 Jan 18;796:153125. doi: 10.1016/j.bbrc.2025.153125. PMID: 41421223
"Streptavidin detection of biotinylated proteins is constrained by its tetrameric structure. A novel rabbit monoclonal anti-biotin antibody (clone BB-IgG) was developed from a high-affinity scFv selected by the ISAAC method. The antibody enabled highly sensitive detection of biotin-labelled proteins by immunoblotting, immunoprecipitation, immunostaining and electron microscopy across animal cells, plants and malarial parasites; BB fused to an engineered stable luciferase (BB-LucYY5) further allowed quantitative analysis of biotinylated proteins in vitro and in immunoprecipitated samples."
(Tags: anti-biotin monoclonal antibody immunoblotting immunoprecipitation; anti-biotin mAb immunofluorescence electron microscopy biotinylated protein detection)
Rémi Pescarmona, et al. J Immunol Methods. 2025 Dec;545:113986. doi: 10.1016/j.jim.2025.113986. PMID: 41135737
"Chimeric antigen receptor T-cell monitoring in peripheral blood is essential for predicting therapeutic outcomes and managing side effects. A dual-platform flow cytometry protocol for CAR-T quantitation was established and evaluated across three flow cytometers using fresh whole blood stained with a biotinylated CD19 or BCMA recombinant protein detected by a PE-conjugated anti-biotin antibody. Repeatability and intermediate precision CVs were consistently below 10 % across instruments and CAR-T proportions up to >3000 cells/μL, demonstrating the reliability of anti-biotin mediated detection for clinical-grade CAR-T enumeration."
(Tags: PE-conjugated anti-biotin monoclonal antibody flow cytometry CAR-T; anti-biotin mAb whole blood CAR-T cell quantitation)
Yiying Zhu, et al. Biochem Biophys Rep. 2024 Jul;38:101711. doi: 10.1016/j.bbrep.2024.101711. PMID: 38681669
"Biotin labeling combined with mass spectrometry is widely used for mapping protein partners, subcellular localization and post-translational modifications. This work improved the elution phase of the immunoaffinity enrichment of biotinylated peptides by adding a high-organic solvent, and developed a new monoclonal anti-biotin antibody that increased the number of identified biotinylated peptides. The antibody was applied to characterize protein interaction sites of the β2 adrenergic receptor via proximity labeling in living cells by immunoblotting and LC-MS/MS, providing a reproducible workflow for site-specific biotinylation studies."
(Tags: anti-biotin monoclonal antibody LC-MS/MS peptide enrichment; monoclonal anti-biotin antibody proximity labeling biotinylation site mapping)
Yuanyuan Li, et al. Food Chem. 2023 Oct 15;421:136143. doi: 10.1016/j.foodchem.2023.136143. PMID: 37463535
"Ultrasensitive sandwich immunoassays for detecting the small molecule semicarbazide (SEM) were developed based on derivatization. Several SEM derivatizing agents were synthesized by linking o-nitrobenzaldehyde and biotin with dihydroxyalkanes of different lengths. A sandwich ELISA was developed using an anti-SEM-NBA antibody and a horseradish peroxidase-labeled anti-biotin antibody as the secondary conjugate, achieving an optimal EC50 of 11.2 pg/mL. Compared with competitive ELISA the method achieved a 30-fold improvement in sensitivity for aquatic product residue detection."
(Tags: HRP-conjugated anti-biotin monoclonal antibody sandwich ELISA; anti-biotin mAb small molecule immunoassay ultrasensitive detection)
Saralee Srivorakul, et al. Vet Sci. 2025 Sep 11;12(9):845. doi: 10.3390/vetsci12090845. PMID: 41012770
"A reverse-transcriptase recombinase polymerase amplification (RT-RPA) assay combined with a lateral flow dipstick (LFD) was developed for rapid detection of Tilapia Lake Virus. The dipstick was prepared with immobilized anti-FITC and anti-biotin capture antibodies compatible with TiLV-specific primers tagged with FITC and biotin. Amplification was completed at 39 °C within 20 min and read by positive band formation on the LFD. The assay achieved a limit of detection of 3.19 copies/µL, representing a 100-fold improvement over RT-PCR-LFD for field-deployable viral diagnostics."
(Tags: anti-biotin monoclonal antibody lateral flow dipstick; anti-biotin mAb recombinase polymerase amplification rapid pathogen detection)

Syd Labs provides the following recombinant anti-Biotin/Digoxin/DNP/Fluorescein monoclonal antibodies:
Recombinant Anti-Biotin Monoclonal Antibodies (Clone F1)
Recombinant Anti-Biotin Monoclonal Antibodies (Clone M33)
Recombinant Anti-Digoxin Monoclonal Antibodies (Clone 5A7)
Recombinant Anti-Digoxin Monoclonal Antibodies (Clone 26-10)
Recombinant Anti-DNP Monoclonal Antibodies (Clone DNP.m3)
Recombinant Anti-Fluorescein Monoclonal Antibodies (Clone 4-4-20)
Recombinant Anti-Fluorescein Monoclonal Antibodies (Clone 4M5.3)

Related Links

See our Privacy Policy